datasheetbank_Logo
データシート検索エンジンとフリーデータシート

SI4743 データシートの表示(PDF) - Silicon Laboratories

部品番号
コンポーネント説明
一致するリスト
SI4743 Datasheet PDF : 68 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
AN388
2.3. FM Test Procedures
The following procedures measure analog audio output. All audio measurements can be duplicated for digital audio
output where applicable. For audio analyzer settings in digital mode, refer to Section 6.1.
2.3.1. Sensitivity
Sensitivity of a receiver is a measure of its ability to receive weak signals and produce an audio frequency output of
usable magnitude and acceptable quality. Sensitivities may be defined with respect to many different
characteristics of the output signal. For the purposes of our testing, sensitivity is the minimum RF level required to
produce an audio output with a specified signal-to-noise and distortion ratio, 26 dB. Please note that the sensitivity
measurement is defined with respect to SINAD and not SNR. Descriptions for these two measurements will be
given in the following sections.
1. Connect test equipment as shown in Figures 1, 2, or 3.
2. Configure the tuner in standard configuration.
3. Configure the audio analyzer:
a. Select Analyze.
b. Set Function = THD+N / SINAD.
i. Set Measurement Mode = SINAD.
ii. Set Unit = dB.
iii. Set Filter = A-weighting.
iv. Set Frequency Limit Low = 300 Hz.
v. Set Frequency Limit High = 15000 Hz.
4. Configure generator #1:
a. Set carrier frequency = 98.1 MHz.
b. Select FM Modulation.
i. Set FM Deviation = 22.5 kHz.
ii. Set Source = LFGEN.
iii. Set LFGEN frequency = 1 kHz.
c. Enable modulation.
d. Enable carrier.
5. Disable generator #2.
6. Adjust generator #1 RF level, VRF0, until audio analyzer SINAD = 26 dB +/- 1 dB.
7. Sensitivity (µV) = VRF0.
12