datasheetbank_Logo
データシート検索エンジンとフリーデータシート

REL150-1005 データシートの表示(PDF) - Astrodyne Corporation

部品番号
コンポーネント説明
一致するリスト
REL150-1005
ASTRODYNE
Astrodyne Corporation ASTRODYNE
REL150-1005 Datasheet PDF : 3 Pages
1 2 3
150 Watt Open Frame Switching Power Supply with PFC
REL150 series
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input Voltage, Full Range:
Active PFC
Input Frequency
Inrush Current
Leakage Current
85-264 VAC
>0.95@115VAC
47-63Hz.
30A @ 115VAC, typ 4
40A @ 230VAC, typ 4
<300uA @ 240VAC
Oper. Temperature
Relative Humidity
Storage Temperature
MTBF
Shock & Vibration
0 to +60 °C 4
10-95%, Description 4
-40 to +85 °C 4
100KHrs
MIL-Std 217F
To MIL-Std 810E
OUTPUT SPECIFICATIONS
Output Power
Minimum Load Requirement
Max Current (A, Peak)
Initial Accuracy
Voltage Adjust
Load Regulation
Cross Regulation
Line Regulation
Temperature Coefficient
Ripple/Noise
Overvoltage Protection
Remote Sense (Singles Only)
Hold Up/Start Up Times
Short Circuit Protection
Current Limit
100W, Conv/150W Forced Air
10%
See Model Selection Chart 7
+/-1%, typ
± 5%, typ
± 1%, typ
+/-5%
± 0.5%, typ
± 0.02%/°C
100mV Pk-Pk, typ
110-150%, Type 2 & 3
250mV compensation
16mS/5Sec, typ
Continuous 4
110-160% typ, Auto Recovery
GENERAL SPECIFICATIONS
Input-Output Isolation
Output-Ground Isolation
Input-Ground Isolation
Efficiency (@ Full Load)
Safety
EMC
3000VAC 5
500VAC
1500VAC
82%, typ
(or See Chart/Curve)
UL60950/EN60950 Approved
EN55022/B, EN61000-3-2,3/A
EN61000--4-2,3,4,5,6,8,11/Cr A
PHYSICAL SPECIFICATIONS
Dimensions
Material Flammability
Construction
Weight
6”x3.83”x1.32”
to UL94V-0
Open Frame
1.15lb
SPECIFICATION NOTES
1) All specifications typical @ 25°C, Nominal Line & Load, unless otherwise
noted.
2) O/P noise measured directly at pins/terminals with 0.1uFbypass, pk-pk @
20MHz bandwidth.
3) Ripple and Noise dependant upon output voltage as specified per particular
model.
4) These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed or implied.
5) Isolation for up to 1 minute duration.
6) No termination necessary with control pin to maintain constant “ON” operation
(if applicable to this model)
7) Max load (peak) specified for 10mS max, 20% duty cycle, minimum load on
all outputs
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
A Blue Number means see respective Specification
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458