First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MP7641
8085
ALE
WR
SOD
8
8
8212
8
ADDRESS BUS
+5
E1
E3
E2
3
A0 to A2
74LS138
ADDRESS
DECODER
DATA BUS
LD
SDI
CLK
MP7641
RST
FROM SYSTEM RESET
Figure 6. 8085 Interface (Simplified Diagram)
NOTES:
1. Clock generated by WR and decoding address 8000
2. Data is clocked into the DAC shift register by executing memory write instructions. the clock input is
generated by decoding address 8000 and WR. Data is then loaded into the DAC register with a memory
write instruction to address 4000.
3. Serial data must be present in the right justified format in registers H & L of the microprocessor.
Rev. 2.00