MITSUBISHI INTELLIGNET POWER MODULES
PM75CTK060
FLAT-BASE TYPE
INSULATED PACKAGE
TOTAL SYSTEM
Symbol
VCC(PROT)
VCC
VCC(surge)
TC
Parameter
Supply voltage protected
by OC & SC
Supply voltage
Supply voltage (surge)
Module case operating temperature
Tstg
Storage temperature
Viso
Isolation voltage
Note 1 : TC measuring point is as shown below.
Conditions
VD = 13.5 ~ 16.5V,
Inverter part, Tj = 125°C start
Applied between : P-N, operating time
Applied between : P-N, surge and non-operating time
(Note 1)
60Hz, sinusoidal, AC · 1 min
Ratings
400
450
500
–20 ~ +100
–40 ~ +125
2500
Unit
V
V
V
°C
°C
Vrms
TC
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise noted)
INVERTER PART
Symbol
Parameter
VCE(sat)
VEC
ton
trr
tc(on)
toff
tc(off)
ICES
Collector-emitter
saturation voltage
FWDi forward voltage
Switching time
Collector-emitter
cutoff current
Test conditions
VD = 15V, ICIN = 10mA
IC = 75A, Tj = 25°C
IC = 75A, Tj = 125°C
–IC = 75A, VD = 15V, ICIN = 0mA
VD = 15V, ICIN = 0mA10mA
VCC = 300V, IC = 75A
Tj = 125°C
(Per 1 arm) Inductive Load
VCE = VCES, ICIN = 0mA
Tj = 25°C
Tj = 125°C
Limits
Min.
Typ.
Max. Unit
1.8
2.7
V
1.85 2.78
2.2
3.3
V
0.6
1.2
0.15
0.5
2.4
µs
0.3
µs
1.1
µs
2.8
3.6
µs
0.6
1.2
µs
1
mA
10
CONTROL PART
Symbol
Parameter
Test conditions
ID
Ith(ON)
Ith(OFF)
OC
SC
toff(OC)
OT
OTr
UV
UVr
IFO(H)
IFO(L)
tFO
Circuit current
Input on threshold current
Input off threshold current
Over current trip level
Short circuit trip level
Over current delay time
Over temperature protection
Supply circuit under
voltage protection
VD = 15V, ICIN = 0mA
VN1-VNC
VXP1-VXPC
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN · VN · WN-VNC
–20°C Tj 125°C, VD = 15V
–20°C Tj 125°C, VD = 15V
VD = 15V
Base-plate
Trip level
Temperature detection, VD = 15V
Reset level
–20°C Tj 125°C
Trip level
Reset level
Fault output current (Note 2) VD = 15V, VFO = 15V
Minimum fault output pulse
width
(Note 2) VD = 15V
Note 2 : Fault output is given only when the internal OC, SC, OT & UV protection.
Fault output of OC, SC protection operate by lower arm.
Fault output of OC, SC protection given pulse.
Fault output of OT, UV protection given pulse while over level. (OT is only N side)
Limits
Min.
Typ.
Max. Unit
40
55
13
18
mA
1
3
5 mA
1
3
5 mA
115
161
A
241
A
10
µs
100
110
120 °C
90
°C
11.5
12.0 12.5
V
12.5
V
0.01 mA
10
15 mA
1.0
1.8
ms