P4C167
MAXIMUM RATINGS(1)
Symbol
Parameter
VCC
Power Supply Pin with
Respect to GND
VTERM
Terminal Voltage with
Respect to GND
(up to 7.0V)
TA
Operating Temperature
Value Unit
–0.5 to +7 V
–0.5 to
VCC +0.5
V
–55 to +125 °C
RECOMMENDED OPERATING
TEMPERATURE AND SUPPLY VOLTAGE
Grade(2)
Ambient
Temperature
Military
–55°C to +125°C
Industrial –40°C to +85°C
Commercial 0°C to +70°C
GND
0V
0V
0V
VCC
5.0V ± 10%
5.0V ± 10%
5.0V ± 10%
Symbol Parameter
TBIAS
Temperature Under
Bias
TSTG
Storage Temperature
PT
Power Dissipation
IOUT
DC Output Current
Value Unit
–55 to +125 °C
–65 to +150 °C
1.0
W
50
mA
CAPACITANCES(4)
VCC = 5.0V, TA = 25°C, f = 1.0MHz
Symbol
Parameter
Conditions Typ. Unit
CIN
COUT
Input Capacitance
VIN = 0V
5 pF
Output Capacitance VOUT = 0V 7 pF
DC ELECTRICAL CHARACTERISTICS
Over recommended operating temperature and supply voltage(2)
Symbol
Parameter
Test Conditions
VIH Input High Voltage
VIL Input Low Voltage
VHC CMOS Input High Voltage
VLC CMOS Input Low Voltage
VCD Input Clamp Diode Voltage VCC = Min., IIN = –18 mA
VOL
Output Low Voltage
(TTL Load)
IOL = +8 mA, VCC = Min.
P4C167
Min Max
2.2 VCC +0.5
–0.5(3)
0.8
P4C167L
Min
Max
Unit
2.2 VCC +0.5 V
–0.5(3)
0.8
V
VCC –0.2 VCC +0.5 VCC –0.2 VCC +0.5 V
–0.5(3) 0.2 –0.5(3) 0.2
V
–1.2
–1.2 V
0.4
0.4 V
VOH
Output High Voltage
(TTL Load)
IOH = –4 mA, VCC = Min.
2.4
2.4
ILI Input Leakage Current
VCC = Max.
VIN = GND to VCC
Mil. –10
+10
–5
Com’l. –5
+5
n/a
ILO
Output Leakage Current
VCC = Max., CE = VIH,
Mil. –10
VOUT = GND to VCC
Com’l. –5
+10
+5
–5
n/a
ISB
Standby Power Supply
Current (TTL Input Levels)
CE VIH
Mil.
VCC = Max .,
Ind./Com’l.
f = Max., Outputs Open
___
___
30
20
___
___
Standby Power Supply
ISB1 Current
(CMOS Input Levels)
CE VHC
VCC = Max.,
Mil.
Ind./Com’l.
___
___
f = 0, Outputs Open
VIN VLC or VIN VHC
15
10
___
___
n/a = Not Applicable
V
+5
n/a
µA
+5
n/a
µA
20 mA
n/a
1.0 mA
n/a
Notes:
1. Stresses greater than those listed under MAXIMUM RATINGS may
cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification
is not implied. Exposure to MAXIMUM rating conditions for extended
periods may affect reliability.
2. Extended temperature operation guaranteed with 400 linear feet per
minute of air flow.
3. Transient inputs with VIL and IIL not more negative than –3.0V and
–100mA, respectively, are permissible for pulse widths up to 20 ns.
4. This parameter is sampled and not 100% tested.