datasheetbank_Logo
データシート検索エンジンとフリーデータシート

N5162A データシートの表示(PDF) - HP => Agilent Technologies

部品番号
コンポーネント説明
一致するリスト
N5162A
HP
HP => Agilent Technologies HP
N5162A Datasheet PDF : 32 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
0.5
0.4
0.3
0.2
0.1
0
–0.1
–0.2
–0.3
–0.4
–0.5
0
Amplitude repeatablity +5 dBm ALC on
850 MHz
1900 MHz
2200 MHz
3500 MHz
5800 MHz
20
40
60
80
Elapsed time (minutes)
100
120
Repeatability measures the ability of the instrument to return to a given
power setting after a random excursion to any other frequency and power
setting. It should not be confused with absolute level accuracy.
0.5
0.4
0.3
0.2
0.1
0
–0.1
–0.2
–0.3
–0.4
–0.5
0
Relative level accuracy at 850 MHz initial power +10 dBm
Upper std dev (1 σ)
Mean
Lower std dev (1 σ)
–20
–40
-60
–80
–100
–120
–140
Final power (dBm)
Relative level accuracy measures the accuracy of a step change from
any power level to any other power level. This is useful for large
changes (i.e. 5 dB steps).
ALC linearity 850 MHz, CW, relative to 0 dBm
0.3
Upper std dev (1 σ)
0.2
Mean
Lower std dev (1 σ)
0.1
0
–0.1
–0.2
–0.3
–20
–15
–10
–5
0
Amplitude (dB)
5
10
ALC linearity 1900 MHz, CW, relative to 0 dBm
0.3
Upper std dev (1 σ)
0.2
Mean
Lower std dev (1 σ )
0.1
0
–0.1
–0.2
–0.3
–20
–15
–10
–5
0
5
10
Amplitude (dB)
9

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]