MITSUBISHI LSIs
SDRAM (Rev.3.2)
Feb.'00
M2V64S20DTP-6,-6L,-7,-7L,-8,-8L (4-BANK x 4,194,304-WORD x 4-BIT)
M2V64S30DTP-6,-6L,-7,-7L,-8,-8L (4-BANK x 2,097,152-WORD x 8-BIT)
M2V64S40DTP-6,-6L,-7,-7L,-8,-8L (4-BANK x 1,048,576-WORD x 16-BIT)
64M Synchronous DRAM
BASIC FUNCTIONS
The M 2V64S20, 30 and 40DTP provides basic functions, bank (row) activate, burst read and write, bank
(row) precharge, and auto and self refresh. Each command is defined by control signals of /RAS, /CAS and
/WE at CLK rising edge. In addition to 3 signals, /CS ,CKE and A10 are used as chip select, refresh option,
and precharge option, respectively. To know the detailed definition of commands, please see the command
truth table.
CLK
/CS
/RAS
/CAS
/WE
CKE
A10
Chip Select : L=select, H=deselect
Command
Command def ine basic commands
Command
Ref resh Option @ref resh command
Precharge Option @precharge or read/write command
Activate (ACT) [/RAS =L, /CAS =/WE =H]
ACT command activates a row in an idle bank indicated by BA.
Read (READ) [/RAS =H, /CAS =L, /WE =H]
READ command starts burst read from the active bank indicated by BA. First output data appears after
/CAS latency. When A10 =H at this command, the bank is deactivated after the burst read (auto-
p recharge,READA)
Write (WRITE) [/RAS =H, /CAS =/WE =L]
WRITE command starts burst write to the active bank indicated by BA. Total data length to be written
is set by burst length. When A10 =H at this command, the bank is deactivated after the burst write
(auto-p recharge, WRITEA).
Precharge (PRE) [/RAS =L, /CAS =H, /WE =L]
PRE command deactivates the active bank indicated by BA. This command also terminates burst read
/write operation. When A10 =H at this command, all banks are deactivated (precharge all, PREA).
Auto-Refresh (REFA) [/RAS =/CAS =L, /WE =CKE =H]
REFA command starts auto-refresh cycle. Refresh address are generated internally. After this
command, the banks are precharged automatically.