datasheetbank_Logo
データシート検索エンジンとフリーデータシート

MP2355DN-Z データシートの表示(PDF) - Monolithic Power Systems

部品番号
コンポーネント説明
一致するリスト
MP2355DN-Z
MPS
Monolithic Power Systems MPS
MP2355DN-Z Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
TM
MP2355 – 3A, 23V, 380KHz STEP-DOWN CONVERTER
TYPICAL PERFORMANCE CHARACTERISTICS (continued)
Circuit of Figure 2, VIN = 12V, VO = 3.3V, L1 = 15µH, C1 = 10µF, C2 = 22µF, TA = +25°C, unless
otherwise noted.
Load Transient
VO, AC
200mV/div.
IL
1A/div.
ILOAD
1A/div.
Short Circuit Protection
Short Circuit Recovery
VOUT
2V/div.
VOUT
2V/div.
IL
2A/div.
IL
2A/div.
MP2355-TPC06
MP2355-TPC07
MP2355-TPC08
PIN FUNCTIONS
Pin #
1
2
3
4
5
6
7
8
Name
SS
BST
VIN
LX
GND
FB
COMP
RUN
Description
Soft-Start Control Input. SS controls the soft-start period. Connect a capacitor from SS to
GND to set the soft-start period. A 0.1µF capacitor sets the soft-start period to 10ms. To
disable the soft-start feature, leave SS unconnected.
High-Side Gate Drive Boost Input. BST supplies the drive for the high-side N-Channel
MOSFET switch. Connect a 10nF or greater capacitor from LX to BST to power the high
side switch.
Power Input. VIN supplies the power to the IC, as well as the step-down converter switches.
Drive VIN with a 4.75V to 23V power source. Bypass VIN to GND with a suitably large
capacitor to eliminate noise on the input to the IC. See Input Capacitor
Power Switching Output. LX is the switching node that supplies power to the output.
Connect the output LC filter from LX to the output load. Note that a capacitor is required
from LX to BST to power the high-side switch.
Ground. (Note: Connect the exposed pad on backside to Pin 5.)
Feedback Input. FB senses the output voltage to regulate that voltage. Drive FB with a
resistive voltage divider from the output voltage. The feedback threshold is 1.222V. See
Setting the Output Voltage
Compensation Node. COMP is used to compensate the regulation control loop. Connect a
series RC network from COMP to GND to compensate the regulation control loop. In some
cases, an additional capacitor from COMP to GND is required. See Compensation
Enable/UVLO. A voltage greater than 2.71V enables operation. For complete low current
shutdown the EN pin voltage needs to be less than 900mV.
MP2355 Rev. 1.5
www.MonolithicPower.com
4
5/1/2006
MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited.
© 2006 MPS. All Rights Reserved.

Share Link: 