datasheetbank_Logo
データシート検索エンジンとフリーデータシート

MLX90366LVS-ADS-200-TU データシートの表示(PDF) - Melexis Microelectronic Systems

部品番号
コンポーネント説明
一致するリスト
MLX90366LVS-ADS-200-TU
Melexis
Melexis Microelectronic Systems  Melexis
MLX90366LVS-ADS-200-TU Datasheet PDF : 34 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MLX90366
TriaxisPosition Sensor Assembly feat. SENT
5. Absolute Maximum Ratings
Supply Voltage, VDD (overvoltage)
Reverse Voltage Protection
Positive Output Voltage
Output Current (IOUT)
Reverse Output Voltage
Reverse Output Current
Operating Ambient Temperature Range, TA
Storage Temperature Range, TS
Magnetic Flux Density
24 V
12 V (breakdown at -14 V)
18 V (breakdown at 24 V)
30 mA (in breakdown)
0.3 V
50 mA (in breakdown)
40°C   150C
40°C   150C
1T
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute maximum
rated conditions for extended periods may affect device reliability.
6. Description
As described on the block diagram the three vector components of the magnetic flux density (BX, BY and
BZ) applied to the IC are sensed through the sensor front-end. The respective Hall signals (VX, VY and VZ)
are generated at the Hall plates and amplified.
The analog signal processing is based on a fully differential analog chain featuring the classic offset
cancellation technique (Hall plate 2-Phases spinning and chopper-stabilized amplifier).
The conditioned analog signals are converted through an ADC (15 bits) and provided to a DSP block for
further processing. The DSP stage is based on a 16 bit RISC micro-controller whose primary function is
the extraction of the position from two (out of three) raw signals (after so-called front-end compensation
steps) through the following function:
 V1,k V2
Where alpha is the magnetic angle (B1, B2), V1 = VX or VY or VZ , V2 = VX or VY or VZ and k is a
programmable factor to match the amplitude of V1 and k V2.
The DSP functionality is governed by the micro-code (firmware F/W) of the micro-controller which is
stored into the ROM (mask programmable). In addition to the magnetic angle extraction, the F/W controls
the whole analog chain, the output transfer characteristic, the output protocol, the programming/calibration
and also the self-diagnostic modes.
The magnetic angular information is intrinsically self-compensated vs. flux density variations. This feature
allows therefore an improved thermal accuracy vs. position sensor based on conventional linear Hall
sensors.
In addition to the improved thermal accuracy, the realized position sensor features excellent linearity
performance taking into account typical manufacturing tolerances (e.g. relative placement between the
Hall IC and the magnet).
MLX90366
Rev. 1.0
Page 7 of 34
Datasheet
25/Jun/13

Share Link: 