datasheetbank_Logo
データシート検索エンジンとフリーデータシート

ML7005 データシートの表示(PDF) - Oki Electric Industry

部品番号
コンポーネント説明
一致するリスト
ML7005
OKI
Oki Electric Industry OKI
ML7005 Datasheet PDF : 25 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
¡ Semiconductor
Timing When DTMF is received
tREJDT
tBRKDT1
tCYCDT
tDETDT
tPOSDT
tBRKDT2
AIN Signal
DTMF Receive Data
SP
tDELDT
tHOLDT
tSP
ML7005
Figure 3 Timing When DTMF is Received
tDETDT : Time to Detect
When Time to Detect is the specified value of tDETDT or more, the DTMF signal is
normally received.
tREJDT : Time to Reject
When Time to Reject is the specified value of tREJDT or less, the input signal is ignored
and the SP and DTMF receive data are not output.
tPOSDT : Interdigit Pause
When there is no input signal for the period of tPOSDT or more, the DTMF receive data
and SP are reset. Even if the receive data is changed, when Interdigit Pause Time is the
value of tPOSDT or less (including the change without Drop Out), SP remains at "0" and
the DTMF receive data may maintain its initial value.
tBRKDT1 : Acceptable Drop Out Time 1
Acceptable Drop Out Time 1 is applied between when the input signal comes and when
SP becomes "0". Even if there is no input signal for the period of tBRKDT1 or less, the SP
and DTMF receive data are normally output.
tBRKDT2 : Acceptable Drop Out Time 2
Acceptable Drop Out Time 2 is applied when SP is "0" (when receive data is output).
Even if there is no input signal during signal reception for the period of tBRKDT2 or less,
SP and DTMF receive data are not reset.
tCYCDT : Signal Repetition Time
Signal Repetition Time should be the specified value of tCYCDT or more so that a signal
is normally received.
tDELDT : Detect Delay Time
The DTMF receive data is output with a delay of the specified value of tDELDT after the
input signal appears.
tHOLDT : Detect Hold Time The SP and DTMF receive data outputs stop with a delay of the
specified value of tHOLDT after the input signal disappears.
tSP :
SP Delay Time
The SP data is output with a delay of the specified value of tSP after the DTMF receive
data is output. The DTMF receive data should be latched after detecting the fall of SP.
12/24