MB88162
■ LOCK-UP TIME
2.7/3.0 V
VDD
Oscillation stabilization
wait time
XIN
VIH
OE
Setting pin VIH
S1, S0,
MLTP
SPRD
OUT
tLK (lock-up time )
The clock oscillation stabilization wait time is required when the power is turned on.
If the OE pin is fixed at “H” level, the maximum time after the power is turned on until the required clock is obtained
is (the oscillation stabilization wait time of input clock to XIN pin) + (the lock-up time “tLK”) .
For the stabilization wait time of input clock to the XIN pin, check the characteristics of the resonator or oscillator
used.
VDD
2.7/3.0 V Oscillation stabilization
wait time
XIN
OE
Setting pin VIH
S1, S0,
MLTP
SPRD
OUT
VIH
tLK (lock-up time )
If the OE pin is used for power down control, the required clock is obtained at most the lock-up time “tLK” after the
OE pin goes “H” level.
16