WDCT Power Amplifier
2400 - 2500 MHz
Rev. V3
Electrical Specifications:
Frequency = 2450 MHz, PIN = -1 to 3 dBm, VCC = 2.4 V, VEN = 2.5 V, TA = 25 °C, Z0 = 50Ω
Parameter
Small Signal Gain
Input Return Loss
Output Power
Power Flatness
PAE
Current
Current, Off
Pdiss
Control Pins
Harmonics
Forward Isolation
Duty Cycle
Test Conditions
Pin = -20 dBm
2.0 V < VCC < 3.0 V
VEN = 0 V
POUT = 25.0 dBm
VEN, Low
VEN, High
Current
2f
3f
VEN = 0 V
Units
dB
dB
dBm
dB
%
mA
µA
W
V
V
mA
dBc
dBc
dB
%
Min.
23
0
2.0
Typ.
27
15
25
3
33
400
3
0.6
3
-54
-42
39
Max
500
10
0.5
2.5
4.0
100
Stability
+1.5 V < VCC < +3.5 V, PIN = -1 to 3 dBm, VSWR < 6:1
-20°C < TC < +70ºC, RBW = 3 MHz max hold
Lead-Free 3 mm 12-Lead PQFN
All spurs < -60 dBc
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Operating the MAAPSS0066
The MAAPSS0066 can be damaged by electrostatic
discharge (ESD). Use proper ESD control
techniques when handling this device. To operate
the MAAPSS0066, turn on VCC before VEN for power
on and turn off VCC after VEN for shutdown.
2
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions North America Tel: 800.366.2266 / Fax: 978.366.2266
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macomtech.com for additional data sheets and product information.
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]