MITSUBISHI SEMICONDUCTORS <Standard-Linear>
M62211P/FP
GENERAL PURPOSE MULTI FUNCTION DC-DC CONVERTER
1-2 Setting Up TIN
1) Setting Up the Level
The TIN terminal is shown in Fig.a. In order for the level of TIN to satisfy the conditions shown in
the table below, the external circuits shown in Fig.b or Fig.c should be used when the external
voltage level of the input is high.
100K
TIN 5
5
50K
3
GND
Fig.a
Fig.b
Items
Symbols min
typ
TIN "H" level
VTINH
2.2
TIN "L" level
VTINL
5
max
VCC
1.0
Fig.c
Unit
V
V
2) Setting Up frequency
The periodical change of TIN is expected to be +30% ~ -20%. The fIN is set to
approximately 1.5 times fOSC
fIN = 1.5 * fOSC
fsoc
1
(Hz)
1.3µs+(23 * 10 *3Cosc )
COSC
TIN
(6/9)