Current Transducer LF 1005-S
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 1000 A
Electrical data
16110
IPN
Primary nominal r.m.s. current
1000
A
I
P
Primary current, measuring range @ ± 24 V
0 .. ± 1500
A
RM Measuring resistance @
TA = 70°C TA = 85°C
RR RR
M min Mmax M min Mmax
with ± 15 V
with ± 24 V
@ ± 1000 A
max
@ ± 1200 A max
@ ± 1000 A max
@ ± 1500 A max
0 18 0 15
0 70 4
5 60.5 10 57.5
5 24 10 21
I
Secondary nominal r.m.s. current
SN
K N Conversion ratio
V
Supply voltage (± 5 %)
C
IC
Current consumption
200
mA
1 : 5000
± 15 .. 24
V
28 (@ ± 24 V) + IS mA
Accuracy - Dynamic performance data
X
Overall accuracy @ I , T = 25°C
εG
L
Linearity error
PN A
I
O
IOT
tr
di/dt
f
Offset current @ I = 0, T = 25°C
P
A
Thermal drift of IO
Response time 1) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
- 10°C .. + 85°C
± 0.4
%
< 0.1
%
Typ Max
± 0.4 mA
± 0.3 ± 0.5 mA
<1
> 100
DC .. 150
µs
A /µ s
kHz
General data
TA
Ambient operating temperature
T
Ambient storage temperature
S
R S Secondary coil resistance @
m
Mass
Standards
TA = 70°C
T = 85°C
A
- 10 .. + 85
°C
- 25 .. + 100 °C
48
51
550
g
EN 50178 : 1997
Features
Closed loop (compensated) current
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0.
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Application Domain
Industrial.
Note : 1) With a di/dt of 100 A/µs.
060821/7
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.