Reliability Qualification
A. High Temperature Reverse Bias ( HTRB )
The purpose of this test is to determine the sensitivity of the product to mobile ion contamination and
related failure mechanisms.
Conditions: JESD22-A108, JIS C 7021 B-8
TA=150℃ VCB=80% max rated VCB
Sample Size
45
#of Fail
0
Cum. Fail%
0.0%
168hrs
0
300hrs
0
B. Pressure Cooker Test ( PCT )
Autoclave ( ACLV )
The purpose of this test is to evaluate the moisture resistance of non-hermetic components under
pressure/temperature conditions.
Conditions: JESD22-A102, JIS C 7021 A-6
TA=121℃ RH=100% P=1 atmosphere (15psig)
Sample Size
45
#of Fail
0
Cum. Fail%
0.0%
48hrs
0
C. Temperature Humidity Bias ( THBT )
The purpose of this test is to evaluate the moisture resistance of non-hermetic components.
The addition of voltage bias accelerates the corrosive effect after moisture penetration has taken place.
with time, this is a catastrophically destructive test.
Conditions: JESD22-A101
TA=85℃ RH=85% VCB=80% max rated VCB
Sample Size
#of Fail
Cum. Fail%
168hrs
300hrs
45
0
0.0%
0
0