█ Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
Test Sample
NO.
Item
Test Condition
Hours/ Size
Cycle
ITR9608
Failure
Judgement
Criteria
Ac/Re
More than
1
Solder Heat
TEMP : 260℃ ± 5 ℃
10 sec
90% of lead to
22 PCs be covered by
0/1
soldering
H : +100℃ 15 mins
2 Temperature Cycle
IR≧U×2
5 min
300 22 PCs Ee≦L×0.8
0/1
cycle
VF≧U×1.2
L : -40℃ 15 min
H : +100℃ 5 min
U :Upper
specification
3
Thermal Shock
10 sec 300
limit
22 PCs
0/1
cycle
L :Lower
L : -10℃
5 min
specification
limit
4 High Temperature TEMP. : +100℃
1000
22 PCs
0/1
Storage
hrs
5 Low Temperature TEMP. : -40℃
1000
22 PCs
0/1
Storage
hrs
6 DC Operating Life VCE=5V
1000
22 PCs
0/1
IF=20mA
hrs
7 High Temperature / 85℃ / 85% R.H.
1000
22 PCs
0/1
High Humidity
hrs
EVERLIGHT ELECTRONICS CO., LTD.
Office: No 25, Lane 76, Sec 3, Chung Yang Rd,
Tucheng, Taipei 236, Taiwan, R.O.C
Tel: 886-2-2267-2000, 2267-9936
Fax: 886-2267-6244, 2267-6189, 2267-6306
http:\\www.everlight.com
Everlight Electronics Co., Ltd.
Device No:CDRX-096-006
http:\\www.everlight.com
Prepared date:08-08-2005
Rev 2
Page: 6 of 6
Prepared by:Denky