NOTES:
1. Typical values are for TA = 25°C and 3.3V supply voltage.
2. LSB: [V(RW)255 – V(RW)0]/255. V(RW)255 and V(RW)0 are V(RW) for the DCP register set to FF hex and 00 hex respectively. LSB is the
incremental voltage when changing from one tap to an adjacent tap.
3. ZS error = V(RW)0/LSB.
4. FS error = [V(RW)255 – VCC]/LSB.
5. DNL = [V(RW)i – V(RW)i-1]/LSB-1, for i = 1 to 255. i is the DCP register setting.
6. INL = V(RW)i – i - LSB – V(RW) for i = 1 to 255.
7. VMATCH = [V(RWx)i – V(RWy)i]/LSB, for i = 0 to 255, x = 0 to 3 and y = 0 to 3.
8.
TCV
=
-------M-----a----x----(--V----(---R-----W------)--i--)---–-----M-----i--n----(--V-----(--R-----W------)--i--)------ × ----1---0----6----- for i = 16 to 240 decimal, T = -40°C to 85°C. Max( ) is the maximum value of the wiper
[Max(V(RW)i) + Min(V(RW)i)] ⁄ 2 125°C voltage and Min ( ) is the minimum value of the wiper voltage over the temperature range.
9. MI = |R255 – R0|/255. R255 and R0 are the measured resistances for the DCP register set to FF hex and 00 hex respectively.
10. Roffset = R0/MI, when measuring between RW and GND.
Roffset = R255/MI, when measuring between RW and RH.
11. RDNL = (Ri – Ri-1)/MI, for i = 32 to 255.
12. RINL = [Ri – (MI • i) – R0]/MI, for i = 32 to 255.
13. RMATCH = (Ri,x – Ri,y)/MI, for i = 0 to 255, x = 0 to 3 and y = 0 to 3.
14.
TCR
=
----[---M-----a----x----(--R-----i--)---–-----M-----i--n----(--R-----i--)--]---- × ----1---0----6-----
[Max(Ri) + Min(Ri)] ⁄ 2 125°C
for i = 32 to 255, T = -40°C to 85°C. Max( ) is the maximum value of the resistance and Min ( ) is the
minimum value of the resistance over the temperature range.
15. This parameter is not 100% tested.
Typical Performance Curves
160
VCC=2.7, T=+85°C
140
120 VCC=2.7, T=-40°C
VCC=2.7, T=+25°C
100
80
60
40
20
VCC=5.5, T=-40°C
VCC=5.5, T=+85°C
VCC=5.5, T=+25°C
0
0
50
100
150
200
250
TAP POSITION (DECIMAL)
FIGURE 1. WIPER RESISTANCE vs TAP POSITION
[I(RW) = VCC / RTOTAL] FOR 50k(U)
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0
2.7
-40°C
+25°C
3.2
3.7
4.2
VCC (V)
+85°C
4.7
5.2
FIGURE 2. STANDBY ICC vs VCC
6
FN8094.1
February 8, 2006