12VOUT
12IOUT
ISL6113, ISL6114
12VGATE
CFILTER
VAUX
CFILTER
IAUX
FIGURE 14. ISL6113 12VMAIN WOC SHUTDOWN
3VGATE
3 IOUT
CFILTER
3VOUT
FIGURE 16. VAUX OC REGULATION AND SHUTDOWN
VAUX
CFILTER
IAUX
FIGURE 15. ISL6113 3VMAIN WOC SHUTDOWN
The VAUX outputs have a different circuit-breaker function.
The VAUX circuit breakers do not incorporate a fast-trip
detector, instead they regulate the current into a fault to
avoid exceeding their operating current limit. The circuit
breaker will trip due to an overcurrent on VAUX when the
programmable CR duration timer, t expires. This use of
FLT
the t timer prevents the circuit breaker from tripping
FLT
prematurely due to brief current transients. See Figures 16
and 17 for illustrations of the VAUX protection performance
into an over current (OC) and more severe OC condition
respectively. The ISL6113, ISL6114 AUX current control
responds proportionally to the severity of the OC condition
resulting in appropriately fast VAUX pull down and current
regulation until tFILTER has expired.
14
FIGURE 17. VAUX WOC REGULATION AND SHUTDOWN
In the fault latch mode set by leaving L/R pin open, following a
fault condition, the outputs can be turned on again via the ON
inputs (if the fault occurred on one of the MAIN outputs), via
the AUXEN inputs (if the fault occurred on the AUX outputs),
or by cycling both ON and AUXEN (if faults occurred on both
the MAIN and AUX outputs). When the circuit breaker trips,
FAULT will be asserted. In the fault retry mode, set by
grounding the L/R pin the ISL6113, ISL6114 will initiate an
automatic restart about every 1.5s until successful.
The ISL6113, ISL6114 current regulation duration (tFILTER)
is set by external capacitors at the CFILTER pins to GND.
Once the CR mode is entered, the external cap is charged
with a 2.5µA current source to 1.25V. Once this threshold
has been reached the IC then turns-off all fault the related
FETs and sets the FAULT output low. For a desired tFILTER,
the value for CCFILTER is given by Equation 4:
CFILTER = -n---o---m-----i-n-5---a0---l0---t-k-F---Ω-I--L---T----E---R---
(EQ. 4)
FN6457.0