datasheetbank_Logo
データシート検索エンジンとフリーデータシート

HT7612B データシートの表示(PDF) - Holtek Semiconductor

部品番号
コンポーネント説明
一致するリスト
HT7612B
Holtek
Holtek Semiconductor Holtek
HT7612B Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
HT7612/HT7612B
Effective Trigger Timing
The effective input trigger signal width should be ³ 24ms. The output is valid either with (1) trigger signal width ³ 0.5
seconds or (2) more than 2 effective trigger inputs within 2 seconds (separation of 2 triggers ³ 0.5s). The separation
time between two TRIAC(RELAY) turn-on time must be more than 1 sec. The trigger timing is shown in Fig.11.
Fig.11 Trigger Timing
Retrigger
When the output of the comparator is a valid signal, the RELAY/TRIAC will be activated and the active duration is con-
trolled by the DT oscillating period. If the previous ²Delay Time tD² has not been exceeded and the next valid signal oc-
curs again, the active duration of the RELAY/TRIAC will be restarted. The timing is shown in Fig.12.
Fig.12 Retrigger