datasheetbank_Logo
データシート検索エンジンとフリーデータシート

OM1905NMM データシートの表示(PDF) - Omnirel Corp => IRF

部品番号
コンポーネント説明
一致するリスト
OM1905NMM Datasheet PDF : 4 Pages
1 2 3 4
OM1905NMM - OM1915NMM
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance θJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W aa
θJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120°C/W
3.5
ELECTRICAL CHARACTERISTICS -5 Volt VIN = -10V, Io = 500mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
VIN = -7.5V to -20V
-4.95
-5.05
V
-4.85
-5.15
V
IO = 5mA to 1.0 A, P < 15W
Line Regulation
VRLINE
VIN = -7.5V to -20V
(Note 1)
12
mV
25
mV
(Note 4)
VIN = -8.0V to -12V
5
mV
12
mV
Load Regulation
VRLOAD
IO = 5mA to 1.5 Amp
(Note 1)
20
mV
25
mV
IO = 250mA to 750 mA
15
mV
30
mV
Standby Current Drain
ISCD
2.5
mA
3.0
mA
Standby Current Drain
ISCD
VIN = -7.0V to -20V
0.4
mA
Change With Line
(Line)
Standby Current Drain
ISCD
IO = 5mA to 1000mA
0.4
mA
Change With Load
(Load)
Dropout Voltage
VDO
VOUT = 100mV, IO = 1.0A
2.5
V
Peak Output Current
IO (pk)
TA = 25°C
1.5
3.3
A
Short Circuit Current
IDS
(Note 2)
VIN = -35V
1.2
A
2.8
A
Ripple Rejection
Output Noise Voltage
(Note 3)
VIN
VOUT
NO
f =120 Hz, VIN = -10V
(Note 3)
TA = 25°C, f =10 Hz to 100KHz
63
60
dB
dB
40
µV/V
RMS
Long Term Stability
(Note 3)
VOUT
t
TA = 25°C, t = 1000 hrs.
75
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
3.5 - 54

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]