HFA04TB60PbF
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter
Min Typ Max Units
Test Conditions
VBR
Cathode Anode Breakdown Voltage 600
V IR = 100µA
1.5 1.8
IF = 4.0A
VFM
Max Forward Voltage
1.8 2.2 V IF = 8.0A
See Fig. 1
IRM
Max Reverse Leakage Current
CT
Junction Capacitance
LS
Series Inductance
1.4 1.7
IF = 4.0A, TJ = 125°C
0.17 3.0 µA VR = VR Rated
See Fig. 2
44 300
TJ = 125°C, VR = 0.8 x VR RatedD Rated
4.0 8.0 pF VR = 200V
See Fig. 3
8.0
nH Measured lead to lead 5mm from
package body
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
trr
trr1
trr2
IRRM1
IRRM2
Qrr1
Qrr2
di(rec)M/dt1
di(rec)M/dt2
Parameter
Reverse Recovery Time
See Fig. 5, 6 & 16
Peak Recovery Current
See Fig. 7& 8
Reverse Recovery Charge
See Fig. 9 & 10
Peak Rate of Fall of Recovery Current
During tb
See Fig. 11 & 12
Min Typ Max Units
Test Conditions
17
28 42
IF = 1.0A, dif/dt = 200A/µs, VR = 30V
ns TJ = 25°C
38 57
TJ = 125°C
IF = 4.0A
2.9 5.2 A TJ = 25°C
3.7 6.7
TJ = 125°C
40 60 nC TJ = 25°C
70 105
TJ = 125°C
280
A/µs TJ = 25°C
235
TJ = 125°C
VR = 200V
dif/dt = 200A/µs
Thermal - Mechanical Characteristics
Tlead
RthJC
RthA
RthS
Wt
T
Parameter
Min
Lead Temperature
Thermal Resistance, Junction to Case
Thermal Resistance, Junction to Ambient
Thermal Resistance, Case to Heat Sink
Weight
Mounting Torque
6.0
5.0
Typ
0.5
2.0
0.07
Max
300
5.0
80
12
10
Units
°C
K/W
g
(oz)
Kg-cm
lbfin
0.063 in. from Case (1.6mm) for 10 sec
Typical Socket Mount
Mounting Surface, Flat, Smooth and Greased
2
www.irf.com