First Prev 11 12
DS2714: Quad Loose Cell NiMH Charger
EXAMPLE TIMING DIAGRAM FOR THE DS2714
N
N +1
N +2
N +3
N +4
N +5
N +6
N +7
N +8
N +9
N +10 N +11
123412341234123412341234123412341234123412341234123
Cell 1
Cell 2
Cell 3
Cell 4
NOTE 2
NOTE 1
Note 1: Cell test time slot for Cell 2.
Note 2: Cell test time slot for Cell 3.
In this timing diagram, the pulses represent charge current into the individual cells. Cell 1 is in Precharge (the timing of Precharge is the same as Top-off). It
gets one charge pulse out of every four available times slots.
Cell 2 is in initially in Fast Charge and it transitions to Topoff charge during the N+7th time interval (Note 1)shown in the diagram.
Cell 3 is in Fast charge. Cell testing is performed during the interval marked Note 2. This cell is not ready to go into Top-off and it resumes Fast charge.
Cell 4 is in maintenance mode, one out of every 32 available time slots gets a charge pulse.