AN84
TX
DAC
at 16 kHz
HT(ω)
HL(ω)
HD(ejω)
at 16 kHz
+
-
RX
+ + ADC at
16 kHz
HR(ω)
++
Figure 3. Model
A model of the DAA and the phone line is shown in
Figure 3. In an ideal system, the analog hybrid yields
perfect cancellation of the near-end echo from the
transmit path. A mismatch between the ac termination
and the load produces an echo that is not removed by
the analog hybrid. To increase the near-end echo
cancellation, the digital hybrid must equalize the
disparity between the impedance mismatch of the ac
termination and the line.
From the above model, the echo is equal to:
Substituting for HL(ω) in the equation results in:
HL 1
=
2
×
-----------Z----L---i-n---e-----------
ZLine + ZACT
1
=
-Z----L---i-n---e----–-----Z----A---C----T-
ZLine + ZACT
If ZLINE and ZACT are matched, the analog hybrid
perfectly cancels the transmit signal.
Substituting this result into the echo equation yields:
echo = HT(ω) × HL(ω) × HR(ω) HT(ω) × HR(ω)
= HT(ω) × HR(ω)[HL(ω) 1]
HL(ω) consists of the DAA’s ac termination in
combination with the impedance of the twisted pair
transmission line terminated at the central office (CO)
by a reference impedance. Figure 4 shows the analog
hybrid circuitry and the HL(ω) model expanded to
include the ac termination and line.
2
ZACT
echo
=
HT(ω) × HR(ω)
-Z----L---i-n---e----–-----Z----A---C----T-
ZLine + ZACT
The model for the HT(ω) and HR(ω) plays a critical role
in this calculation. The models are quite complex, and
sampled data of the models are necessary to calculate
the hybrid coefficients. Contact Silicon Labs to acquire
the sampled data of the HT(ω) and HR(ω) models.
A group delay, which was not illustrated in the model,
must also be taken into consideration. Internal DSP and
filters cause this delay. Taking the group delay into
account, the echo is equal to:
echo
=
HT(ω)
×
HR(ω)
×
[HL(ω)
1
]e
----j--2----π------
16000
×
g d⎠⎞
-+
+
ZLINE
Figure 4. HL(ω)–1 Model
where gd is the group delay.
The digital hybrid must cancel the echo by intentionally
adding the negative of the echo. The HD(ω) should be:
⎝⎛1----6j--2-0---π-0---0-- × gd⎠⎞
HD(ω) = –HT(ω) × HR(ω) × [HL(ω) 1]e
2
Rev. 0.6