Data Sheet
ADIS16223
CAPTURE/ALARM CONFIGURATION
Table 14 provides a list of the control registers for the user
MANUAL MODE
configuration of the capture function. The address column in
Table 14 represents the lower byte address for each register.
Table 16 provides an example configuration sequence for manual
mode. When using the factory default configuration, the first
Table 14. Capture Configuration Register Summary
step in this example is unnecessary. Use the manual trigger to
Register
Lower Byte
start the data capture process.
Name
Address
Description
Table 16. Manual Mode Configuration Example
CAPT_CTRL 0x1C
Capture configuration
DIN
Description
CAPT_PRD 0x1E
Capture period (automatic mode)
ALM_MAGX 0x20
X-axis alarm threshold (event mode)
0x9C00 Set CAPT_CTRL[7:0] = 0x00 to select manual mode
ALM_MAGY
ALM_MAGZ
ALM_S_MAG
ALM_CTRL
DIO_CTRL
E GLOB_CMD
0x22
0x24
0x26
0x28
0x36
0x3E
Y-axis alarm threshold (event mode)
Z-axis alarm threshold (event mode)
System alarm
Alarm control (event)
Digital I/O configuration
Capture commands
The CAPT_CTRL register in Table 15 provides the primary user
control for capture mode configuration. It provides four different
T modes of capture: manual, automatic, event, and extended.
Configure the mode by writing to the CAPT_CTRL register,
then use either GLOB_CMD[11] (see Table 27) or one of the
E digital I/O lines (DIO1 or DIO2) as a manual trigger to start
operation. Use the DIO_CTRL register in Table 28 to configure
either DIO1 or DIO2 as a manual trigger input line. The manual
trigger can also stop a capture event that is processing and
L return the device to an idle state.
Table 15. CAPT_CTRL Bit Descriptions
Bits Description (Default = 0x0020)
O [15:10] Reserved
[9:8] Extended mode channel selection
00 = x-axis
01 = y-axis
S 10 = z-axis
11 = reserved
[7]
Band-pass filter, 1 = enabled
[6]
Automatically store capture buffers to flash upon alarm
B trigger, 1 = enabled
[5:4] Pre-event capture length for event mode
00 = 64 samples
O 01 = 128 samples
0xBF08 Set GLOB_CMD[11] = 1 to start the data capture
AUTOMATIC MODE
Table 18 provides a configuration example for automatic mode,
where the manual trigger results in a data capture and then begins a
countdown sequence to start another data capture. This example
also uses the option for shutting down the device to save power
after the data capture completes. The CAPT_PRD register in
Table 17 provides users with the ability to establish the countdown
time in automatic mode.
Table 17. CAPT_PRD Register Bit Descriptions
Bits Description (Default = 0x0000)
[15:10] Reserved
[9:8] Scale for data bits
00 = 1 second/LSB
01 = 1 minute/LSB
10 = 1 hour/LSB
[7:0] Data bits, binary format
Table 18. Automatic Mode Configuration Example
DIN
Description
0x9F02 Set CAPT_PRD[15:8] = 0x02 to set time scale to hours
0x9E18 Set CAPT_PRD[7:0] = 0x18 to set the period to 24 hours
0x9C06 Set CAPT_CTRL[7:0] = 0x06 to select automatic trigger
mode and enable shutdown in between captures
0xBF08 Set GLOB_CMD[11] = 1 to execute a capture, shut down,
and begin the 24-hour countdown for the next capture
10 = 256 samples
11 = 512 samples
[3:2] Capture mode
00 = manual
01 = automatic
10 = event
11 = extended
[1]
Power-down between capture events, 1 = enabled
[0]
Reserved
Rev. A | Page 11 of 20