datasheetbank_Logo
データシート検索エンジンとフリーデータシート

ACT6390MH-T データシートの表示(PDF) - Active-Semi, Inc

部品番号
コンポーネント説明
一致するリスト
ACT6390MH-T Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
fZ(ESR)
=
2π
1
× 33μF
× 0.5
=
9.64kHz
(31)
fZ(ESR) < fC
CCOMP2
= RESR ×COUT
RCOMP
= 0.5×33μF
233k
= 70.8pF
Choose CCOMP2 = 82pF
(32)
Rectifier Selection
For optimal performance, the rectifier should be a
Schottky rectifier that is rated to handle both the
output voltage as well as the peak switch current.
Over Voltage Protection
The ACT6390 and ACT6391 both feature internal
automatic over-voltage protection (OVP). Once the
outputs achieve regulation, if the voltage at FB falls
below 0.125V the controller will automatically dis-
able and latch off, preventing the controller from
running open-loop and potentially damaging the IC
and load.
To re-enable the converters, simply cycle the EN
pin or remove and reapply power to the input.
Shutdown
Drive EN low to disable the IC and reduce the sup-
ply current to just 0.1µA. As with all non-
synchronous step-up DC/DC converters, the exter-
nal Schottky diode provides a DC path from the in-
put to the output in shutdown. As a result, the out-
put drops to one diode voltage drop below the input
in shutdown.
Thermal Shutdown
The ACT6390 and ACT6391 both feature integrated
thermal overload protection. Both devices are auto-
matically disabled when their junction temperatures
exceed 160°C, and automatically re-enable when
the die temperature decreases by 20°C.
ACT6390/ACT6391
Rev 1, 22-Aug-13
Innovative PowerTM
-8-
www.active-semi.com
Copyright © 2013 Active-Semi, Inc.

Share Link: 