2916
DUAL FULL-BRIDGE
MOTOR DRIVER
LOGIC CONTROL OF OUTPUT CURRENT
Two logic
winding current
laetv1e0l i0n%pu, t6s7(%l0 ,a3n3d%I1,)
allow digital
or 0% of the
selection of the
maximum level
motor
per
the table. The 0% output current condition turns OFF all drivers in the
bridge and can be used as an OUTPUT ENABLE function.
CURRENT-CONTROL TRUTH TABLE
l0
I1
Output Current
L
L
VREF/10 RS = ITRIP
H
L
VREF/15 RS = 2/3 ITRIP
L
H
VREF/30 RS = 1/3 ITRIP
H
H
0
These logic level inputs greatly enhance the implementation of
µP-controlled drive formats.
motorDautraincgohnasltfa-snttetporoqpueerabteiotnwse,etnhealll0
paonsditli1oanlsloiwn
the µP to control
an eight-step
the
TYPICAL APPLICATION
STEPPER
MOTOR
1
2
RS
3
RC
2
4
CC
5
6
7
FROM
µP
VREF
56 k
RT
8
99
10 θ 2
11
12
820 pF
CT
VBB
24
RS
23
1
RC
22
CC
21
V
BB
+
20
19
18
17
θ1 16
15
14
VCC 13
FROM
µP
V
REF
+5 V
820 pF
CT
56 k
RT
Dwg. EP-008B1
sequence. This is accomplished by digitally
selecting 100% drive current when only one
phase is ON and 67% drive current when two
phases are ON. Logic
turn OFF all drivers to
highs
allow
roanpibdocthurlr0eanntd
l1
decay when switching phases. This helps to
ensure proper motor operation at high step
rates.
The logic control inputs can also be
used to select a reduced current level (and
reduced power dissipation) for ‘hold’ condi-
tions and/or increased current (and available
torque) for start-up conditions.
GENERAL
The PHASE input to each bridge
determines the direction motor winding
current flows. An internally generated
deadtime (approximately 2 µs) prevents
crossover currents that can occur when
switching the PHASE input.
All four drivers in the bridge output can
rbeesutultrinnegdinOaFFfasbtectwurereenntsdteepcsay(l0th=rol1užg2h.4theV)
internal output clamp and flyback diodes. The
fast current decay is desirable in half-step and
high-speed
inputs float
applications.
high.
The
PHASE,
l0,and
I1
Varying the reference
provides continuous control
vooflttahgeep(eVaRkEFlo) ad
current for micro-stepping applications.
Thermal protection circuitry turns OFF
all drivers when the junction temperature
reaches +170°C. It is only intended to protect
the device from failures due to excessive
junction temperature and should not imply
that output short circuits are permitted. The
output drivers are re-enabled when the
junction temperature cools to +145°C.
The UDN2916B/EB/LB output drivers
are optimized for low output saturation
voltages—less than 1.8 V total (source plus
sink) at 500 mA. Under normal operating
conditions, when combined with the excellent
thermal properties of the batwing package
design, this allows continuous operation of
both bridges simultaneously at 500 mA.