HD74CDCV857
Electrical Characteristics
Item
Symbol Min
Typ *1 Max Unit Test Conditions
Input clamp CLK, CLK
VIK
voltage
FBIN, FBIN, G
—
—
–1.2 V
II = –18 mA, VDDQ = 2.3 V
Output voltage
VOH
VOL
Input current
II
Input capacitance
CI
Delta input capacitance CDI
Supply current
DICC
AI CC
Supply current in power ICCpd
down mode
VDDQ–0.2 —
1.7
—
—
—
—
—
—
—
2.5
—
–0.25 —
—
250
—
9
—
—
—
—
0.2
0.6
±10
3.5
0.25
300
12
100
V
IOH = –100 µA, VDDQ = 2.3 to 2.7 V
IOH = –12 mA, VDDQ = 2.3 V
IOL = 100 µA, VDDQ = 2.3 to 2.7 V
IOL = 12 mA, VDDQ = 2.3 V
µA VI = 0 V to 2.7 V, VDDQ = 2.7 V
pF CLK and CLK, FBIN and FBIN
pF CLK and CLK, FBIN and FBIN
mA f = 170 MHz, VDDQ = AVCC = 2.7 V,
All Yx, Yx pin = open
µA
Note: 1. For conditions shown as Min or Max, use the appropriate value specified under recommended
operating conditions.
7