CF1156 series
SPECIFICATIONS
Absolute Maximum Ratings
Parameter
Supply voltage range
Input voltage range
Operating temperature range
Storage temperature range
Symbol
VDD − VSS
V IN
Topr
T stg
Electrical Characteristics
Ta = 25°C, VSS = 0V, VDD = 3.0V
Condition
Parameter
Operating voltage
Current consumption1
Current consumption2
LH, OSH LOW-level input voltage
LH, OSH HIGH-level input voltage
LH, OSH LOW-level input current
LH, OSH HIGH-level input current
BO LOW-level output current
BO HIGH-level output current
LO LOW-level output current
LO HIGH-level output current
TO oscillator frequency
TO oscillator start voltage
TO oscillator stop voltage
1. Measurement circuit
Symbol
Condition
V DD
IDD1
IDD2
V IL
V IH
I IL
I IH
I OL1
I OH1
I OL2
I OH2
f OSC
V DOB
V DOS
Non-play mode
Melody modes: BO, LO open
VIL = 0.8V
VIH = 3.0V
VOL = 1.0V
VOH = 2.0V
VOL = 1.0V
VOH = 2.0V
A VDD
Rating
Unit
−0.3 to 5.0
V
VSS − 0.2 to VDD + 0.2
V
−20 to 80
°C
−65 to 150
°C
Rating
Unit
min
typ
max
2.0
3.0
3.6
V
–
0.01
0.6
µA
–
100
200
µA
–
–
VSS + 0.2
V
VDD – 0.2
–
–
V
0.7
9.0
18
µA
0.7
9.0
18
µA
4.0
–
–
mA
4.0
–
–
mA
10
–
–
mA
8
–
–
mA
35
50
65
kHz
–
–
2.0
V
–
–
2.0
V
3.0V
VSS
2. Measurement circuit
A VDD
3.0V
LH VSS
SEIKO NPC CORPORATION —3