Parameter definitions
4.5
Output voltage accuracy
The output voltage accuracy is the difference between the actual output voltage and the
theoretical output voltage. Ideally, the current sensing output voltage should be equal to the
input differential voltage multiplied by the theoretical gain, as in the following formula:
Vout-th=Av . Vsense
The actual value is very slightly different, mainly due to the effects of:
the input offset voltage Vos,
non-linearity
Figure 22. Vout vs. Vsense theoretical and actual characteristics
6OUT
!CTUAL
)DEAL
6OUTACCURACYFOR6 SENSEM6
M6
6SENSE
!-
The output voltage accuracy, expressed in percentage, can be calculated with the following
formula:
ΔVout
=
a----b----s---(---V----o---u----t-------(---A----v-----------V-----s---e---n---s---e----)--)
Av Vsense
with Av = 20 V/V for TSC101A, Av = 50 V/V for TSC101B and Av = 100 V/V for TSC101C.
Doc ID 13313 Rev 3