MAX31850/MAX31851
Cold-Junction Compensated, 1-Wire
Thermocouple-to-Digital Converters
Table 1. Thermocouple Wire Connections and Nominal Sensitivities
TYPE
K
J
N
R
S
T
E
T- WIRE
T+ WIRE
TEMP RANGE (°C)
Alumel
Chromel
Constantan
Iron
Nisil
Nicrosil
Platinum
Platinum/Rhodium
Platinum
Constantan
Platinum/Rhodium
Copper
Constantan
Chromel
-270 to +1372
-210 to +1200
-270 to +1300
-50 to +1768
-50 to +1768
-270 to +400
-270 to +1000
SENSITIVITY (µV/°C)
41.276
(0NC to +1000NC)
57.953
(0NC to +750NC)
36.256
(0NC to +1000NC)
10.506
(0NC to +1000NC)
9.587
(0NC to +1000NC)
52.18
(0NC to +400NC)
76.373
(0NC to +1000NC)
COLD-JUNCTION
SENSITIVITY (µV/°C)
(0NC TO +70NC)
40.73
52.136
27.171
6.158
6.181
41.56
44.123
Conversion Functions
During the conversion time, tCONV, three functions are
performed: the temperature conversion of the internal
cold-junction temperature, the temperature conversion of
the external thermocouple, and the detection of thermo-
couple faults.
When executing the temperature conversion for the inter-
nal cold-junction compensation circuit, the connection to
signal from the external thermocouple is opened (switch
S4) and the connection to the cold-junction compensa-
tion circuit is closed (switch S5). The internal T- reference
to ground is still maintained (switch S3 is closed) and
the connections to the fault-detection circuit are open
(switches S1 and S2).
When executing the temperature conversion of the
external thermocouple, the connections to the internal
fault-detection circuit are opened (switches S1 and S2 in
the Block Diagram) and the switch connecting the cold-
junction compensation circuit is opened (switch S5). The
internal ground reference connection (switch S3) and
the connection to the ADC (switch S4) are closed. This
allows the ADC to process the voltage detected across
the T+ and T- terminals. If T+ and T- are unconnected,
the thermocouple temperature sign bit is 0 (MSbit of
Scratchpad Byte 1), and the remainder of the thermo-
couple temperature value is 1.
During fault detection, the connections from the exter-
nal thermocouple and cold-junction compensation
circuit to the ADC are opened (switches S4 and S5,
see the Block Diagram). The internal ground reference
on T- is also opened (switch S3). The connections to
the internal fault-detection circuit are closed (switch
S1 and S2). The fault-detection circuit tests for shorted
connections to VDD or GND on the T+ and T- inputs,
as well as looking for an open thermocouple condi-
tion. Bits 0, 1, and 2 of the internal (cold junction)
temperature data are normally low. Bit 2 goes high to
indicate a thermocouple short to VDD, bit 1 goes high
to indicate a thermocouple short to GND, and bit 0
goes high to indicate a thermocouple open circuit. If
any of these conditions exists, bit 0 of the cold-junction
compensated thermacouple temperature data, which
is normally low, also goes high to indicate that a fault
has occurred.