MIL-PRF-19500/420H
* 4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table VIa (JANS) and table VIb (JAN, JANTX and JANTXV) of MIL-PRF-19500.
Electrical measurements (end-points) requirements shall be in accordance with the applicable inspections of table I,
subgroup 2 herein. For delta requirements see table III herein.
* 4.4.2.1 Group B inspection, table VIa (JANS) of MIL-PRF-19500. For B5, if a failure occurs, resubmission shall
be at the test conditions of the original sample.
Subgroup
Method Condition
B3
1056 0°C to +100°C, 25 cycles.
B3
1051 -55°C to +175°C, 100 cycles.
B3
4066 IFSM = rated IFSM (see col. 5 of 1.3); 10 surges of 8.3 ms each at 1 minute
intervals, superimposed on IO = 0, VRWM = 0.
B4
1037 IO = IO2 rated minimum (see col. 4 of 1.3)
VR = rated VRWM (see col. 3 of 1.3 and 4.5.5); 2,000 cycles.
B5
1027 IO = IO2 rated minimum (see col. 4 of 1.3); apply VR = rated VRWM (see col. 3 of 1.3
and 4.5.2) adjust IO to achieve TJ minimum; f = 50-60 Hz.
Option 1: TA = + 30°C max. ; TJ = 225°C minimum; t = 216 hours; n = 45 c = 0.
or
Option 2: TA = + 100°C max. ; TJ = 275°C minimum; t = 96 hours, n = 22,
c = 0.
*
B6
3101
or
4081
RθJL (maximum) 22°C/W; L = .375 inch (9.53 mm).
For surface mount devices (US version), RθJEC 11°C/W.
B7
Peak reverse power, see 4.5.5. PRM 1,000 W. Test shall be performed on
each sublot; sampling plan n = 10, c = 0, electrical end-points, see table I,
subgroup 2 herein.
* 4.4.2.2 Group B inspection, table VIb (JAN, , JANTX and JANTXV of MIL-PRF-19500).
Subgroup
Method Condition
B2
1056 0°C to +100°C, 10 cycles.
*
B2
1051 -55°C to +175°C, 25 cycles.
B3
1027 TJ = 150°C minimum (see 4.5.2.1). Adjust IO to achieve the required TJ; apply
VR = rated VRWM (see col. 3 of 1.3), f = 50-60 Hz (see 4.5.2).
B5
Not applicable .
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table VII of MIL-PRF-19500. Electrical measurements (end-points) shall be in
accordance with table I, subgroup 2 herein. See table III herein for delta limits when applicable.
13