datasheetbank_Logo
データシート検索エンジンとフリーデータシート

CS5460A データシートの表示(PDF) - Cirrus Logic

部品番号
コンポーネント説明
一致するリスト
CS5460A Datasheet PDF : 54 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CS5460A
complete isolation from the power lines. This isola-
tion is achieved using three transformers. One
transformer is a general-purpose voltage trans-
former, used to supply the on-board DC power to
the CS5460A. A second transformer is a high-pre-
cision, low-impedance voltage transformer (often
called a ‘potential transformer’) with very little
roll-off/phase delay, even at the higher harmonics.
A current transformer is then used to sense the line
current. A burden resistor placed across the sec-
ondary of the current transformer creates the cur-
rent-sense voltage signal, for the CS5460A’s
current channel inputs. Because the CS5460A is
not directly connected to the power mains, isola-
tion is not required for the CS5460A’s digital inter-
face.
Figure 8 shows the CS5460A configured to mea-
sure power in a single-phase 3-wire system. In
many 3-wire residential power systems within the
United States, only the two Line terminals are
available (neutral is not available). Figure 9 shows
how the CS5460A can be configured to meter a
3-wire system when no neutral is available.
120 VAC
N
L
500
500
5 k
10
10 k
470 nF
+ 100 µF
0.1 µF
14
VA+
0.1 µF
3
VD+
R2
R1
To Service
R*V-
R*I-
RShunt
R*
I+
CS5460A
9 VIN+
C* *
V+
C*Vd*iff
PFMON 17
CPUCLK 2
XOUT 1
C* *
V-
10 VIN-
XIN 24
15 IIN-
C*I-*
RESET 19
C*Id*iff
NOTE: Current channel
input measures voltage
CS 7
(just like voltage input).
SDI 23
16 IIN+
SDO 6
SCLK 5
C*I+*
12 VREFIN
INT 20
22
11 VREFOUT
EDIR 21
0.1 µF
EOUT
VA- DGND
13
4
* Refer to Input Protection
** Refer to Input Filtering
2.5 MHz to
20 MHz
Optional
Clock
Source
Serial
Data
Interface
Mech. Counter
or
Stepper Motor
Figure 6. Typical Connection Diagram (One-Phase 2-Wire, Direct Connect to Power Line)
17

Share Link: 