datasheetbank_Logo
データシート検索エンジンとフリーデータシート

CS5376A データシートの表示(PDF) - Cirrus Logic

部品番号
コンポーネント説明
メーカー
CS5376A Datasheet PDF : 107 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CS5376A
Geophone
or
Hydrophone
Sensor
Geophone
or
Hydrophone
Sensor
Geophone
or
Hydrophone
Sensor
Geophone
or
Hydrophone
Sensor
CS3301
M
CS3302
U
AMP
X
CS3301
M
CS3302
U
AMP
X
CS3301
M
CS3302
U
AMP
X
CS3301
M
CS3302
U
AMP
X
CS5371
CS5372
∆Σ
Modulator
CS5371
CS5372
∆Σ
Modulator
CS5376A
Digital Filter
CS4373
Test
DAC
System Telemetry
µController
or
Configuration
EEPROM
Communication
Interface
Figure 9. Multi-Channel System Block Diagram
3. SYSTEM DESIGN WITH CS5376A
Figure 9 illustrates a simplified block diagram of
the CS5376A in a multi-channel measurement sys-
tem.
Up to four differential sensors are connected
through CS3301/02 differential amplifiers to the
CS5371/72 ∆Σ modulators, where analog to digital
conversion occurs. Each modulators 1-bit output
connects to a CS5376A MDATA input, where the
oversampled ∆Σ data is decimated and filtered to
24-bit output samples at a programmed output rate.
These output samples are buffered in an 8-deep
data FIFO and passed to the system telemetry on
command.
System self tests are performed by connecting the
CS5376A test bit stream (TBS) generator to the
CS4373 test DAC. Analog tests drive differential
signals from the CS4373 test DAC into the multi-
plexed inputs of the CS3301/02 amplifiers or di-
rectly to the sensors through external analog
switches. Digital loopback tests internally connect
the TBS digital output directly to the CS5376A
modulator inputs.
3.1 Power Supplies
The multi-channel system shown in Figure 9 typi-
cally operates from a ±2.5 V or 5 V analog power
supply and a 3.3 V digital power supply. The
CS5376A logic core can be powered from 3 V to
minimize power consumption, if required.
3.2 Reset Control
System reset is required only for the CS5376A de-
vice, and is a standard active low signal that can be
generated by a power supply monitor or microcon-
troller. Other system devices default to a power-
down state when the CS5376A is reset.
19

Share Link: 