ACS714
Automotive Grade, Fully Integrated, Hall Effect-Based Linear Current Sensor IC
with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor
x20A PERFORMANCE CHARACTERISTICS over Range E: TA = –40°C to 85°C1, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min. Typ. Max. Units
Optimized Accuracy Range
IP
–20
20
A
Sensitivity
Sens Over full range of IP, TA = 25°C
96
100
104 mV/A
Noise
VNOISE(PP)
Peak-to-peak, TA = 25°C, 100 mV/A programmed Sensitivity,
CF = 47 nF, COUT = open, 2 kHz bandwidth
11
mV
Zero Current Output Slope
∆VOUT(Q)
TA = –40°C to 25°C
TA = 25°C to 150°C
–0.34
mV/°C
–0.07
mV/°C
Sensitivity Slope
∆Sens
TA = –40°C to 25°C
TA = 25°C to 150°C
0.017
– mV/A/°C
–0.004
– mV/A/°C
Electrical Output Voltage
VOE
IP = 0 A
–30
30
mV
Total Output Error2
ETOT IP = ±20 A, TA = 25°C
±1.5
%
1Device may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature,
TJ(max), is not exceeded.
2Percentage of IP, with IP = 20 A. Output filtered.
x20A PERFORMANCE CHARACTERISTICS over Range L: TA = –40°C to 150°C1, CF = 1 nF, and VCC = 5 V, unless otherwise specified
Characteristic
Symbol
Test Conditions
Min. Typ. Max. Units
Optimized Accuracy Range
IP
–20
20
A
Sensitivity
Sens
Over full range of IP, TA = 25°C
Over full range of IP, TA = –40°C to 150°C
100
mV/A
94
104 mV/A
Noise
VNOISE(PP)
Peak-to-peak, TA = 25°C, 100 mV/A programmed Sensitivity,
CF = 47 nF, COUT = out, 2 kHz bandwidth
11
mV
Zero Current Output Slope
∆VOUT(Q)
TA = –40°C to 25°C
TA = 25°C to 150°C
–0.34
mV/°C
–0.07
mV/°C
Sensitivity Slope
∆Sens
TA = –40°C to 25°C
TA = 25°C to 150°C
0.017
– mV/A/°C
–0.004
– mV/A/°C
Electrical Output Voltage
VOE
IP = 0 A
–40
40
mV
Total Output Error2
ETOT
IP = ±20 A, TA = 25°C
IP = ±20 A, TA = –40°C to 150°C
±1.5
%
–5
5
%
1Device may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature,
TJ(max), is not exceeded.
2Percentage of IP, with IP = 20 A. Output filtered.
Allegro MicroSystems, LLC
6
115 Northeast Cutoff, Box 15036
Worcester, Massachusetts 01615-0036 (508) 853-5000
www.allegromicro.com

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]