Philips Semiconductors
NE56610/11/12 Series
System Reset
Application Information
When the manual reset is not needed, the M/R, manual reset
pin is connected to ground as shown in Figure 16 - Typical Hard
Reset Circuit. A capacitor connected from VCC to ground is
recommended when the VCC supply impedance is appreciably
high. This may be the situation with a poor quality or aged
battery.
The second example, shown in Figure 17 - Manual Reset
Circuit, incorporates a manual reset switch from the M/R pin to
VCC. When the manual switch is closed, VOUT reset is logic
high. Conversely, when it is opened, VOUT reset is logic low. As
a precaution a clamp diode is placed from the M/R pin to ground
to insure that the pin does not go below - 0.3V.
Figure 16. Typical Hard Reset Circuit
Figure 17. Manual Reset Circuit
To VCC
RL
5
VCC
4
VOUT
To CPU
Reset Pin
To VCC
Manual
Switch
RL
5
VCC
4
VOUT
To CPU
Reset Pin
M/R SUB GND
123
Clamp
Diode
M/R SUB GND
123
Test Circuits
Figure 16. Test Circuit 1
A2
A1
10µF
/ 10V
VCC
V1
VRES
RL
5
VCC
4
VOUT
M/R SUB GND V2
12
3
Figure 17. Test Circuit 2
Input
Pulse
5
VCC
4
VOUT
RL
10µF
/ 10V
M/R SUB GND
1
2
3
CRT
CL = 100pF
5.0 V
February 23, 2001
A - DC Ammeter
V = DC Voltmeter
Input Pulse
VS typ +0.4V
VS typ -0.4V
8 of 9
CRT = Oscilliscope
0V