MITSUMI
System Reset (with battery back-up) PST620, 621
Timing Chart
PST620
VCC1
4.2V
VCC2
2.15V
CE
TC
Delay
Delay
RE
AC power supply
Note : Connect VAC pin to VCC when not using.
AC rectifier or
regulator
primary side
VTX
CE
Note 1: VTH is set at 2.0V and hysteresis voltage at 90mV.
1. Use a resistor to divide the detected voltage so that it equals VTH when monitoring regulator
primary side power supply.
2. When monitoring AC voltage rectified as in the application circuit, set so that it equals VTH by
lowering the constant and dividing with a resistor. Refer to application circuit diagram.
Note 2: VAC input and VS1 are OR, so either signal makes CE low when power outage is detected.
PST621
AC
VCC1 4.2V
CE
MODE
VCC2 3.1V
RESET
Application Circuits
VAC input : Power supply transformer secondary voltage detection

Share Link: 