MOSEL VITELIC
V55C2128164V(T/B)
Absolute Maximum Ratings*
Operating temperature range (commercial)0 to 70 °C
Operating temperature range (extended) -25 to 85 °C
Storage temperature range ............... -55 to 150 °C
Input/output voltage .................. -0.3 to (VCC+0.3) V
Power supply voltage .......................... -0.3 to 3.6 V
Power dissipation .......................................... 0.7 W
Data out current (short circuit) ...................... 50 mA
*Note:
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage of the device.
Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
Operating Currents TA = 0 to 70 °C(Commercial)/-25 to 85 °C(Extended);
VSS = 0 V; VCC= 2.5 V,VCCQ = 1.8V(Recommended Operating Conditions unless otherwise noted)
Max.
Symbol Parameter & Test Condition
-6 -7 / -7PC -8PC 10 Unit Note
ICC1
Operating Current
tRC = tRCMIN., tRC = tCKMIN.
Active-precharge command cy-
cling, without Burst Operation
1 bank operation
190
170
150
130
mA
7
ICC2P
ICC2PS
Precharge Standby Current
in Power Down Mode
CS =VIH, CKEVIL(max)
ICC2N
ICC2NS
Precharge Standby Current
in Non-Power Down Mode
CS =VIH, CKEVIL(max)
ICC3N
ICC3P
No Operating Current
tCK = min, CS = VIH(min)
bank ; active state ( 4 banks)
tCK = min.
tCK = Infinity
tCK = min.
tCK = Infinity
CKE VIH(MIN.)
1.5
1.5
1.5
1.5
mA
7
1
1
1
1
mA
7
55
45
35
25
mA
5
5
5
5
mA
65
55
45
35
mA
CKE VIL(MAX.)
10
10
10
10
mA
(Power down mode)
ICC4
Burst Operating Current
tCK = min
Read/Write command cycling
130
110
90
70
mA 7,8
ICC5
Auto Refresh Current
tCK = min
Auto Refresh command cycling
270
250
210
190
mA
7
ICC7 Deep Power down Current
10
10
10
10
uA
Notes:
7. These parameters depend on the cycle rate and these values are measured by the cycle rate under the minimum value of tCK and
tRC. Input signals are changed one time during tCK.
8. These parameter depend on output loading. Specified values are obtained with output open.
V55C2128164V(T/B) Rev. 1.2 August 2002