Recommended Operating Conditions
Item
Supply voltage
Input voltage
Output voltage
Operating temperature
Input rise/fall time
Symbol
VCC
VIN
VOUT
Topr
tr, tf
Ratings
2 to 6
0 to VCC
0 to VCC
–40 to +85
0 to 1000 (VCC = 2.0 V)
0 to 500 (VCC = 4.5 V)
0 to 400 (VCC = 6.0 V)
Unit
V
V
V
°C
ns
Electrical Characteristics
Item
VCC
Symbol (V)
Input voltage VIH
2.0
4.5
6.0
VIL
2.0
4.5
6.0
On resistance RON
2.0
4.5
6.0
Leak current IS
6.0
(off)
IS
6.0
(on)
Input current IIN
6.0
Operating
ICC
6.0
current
Ta = 25°C
Ta = –40 to 85°C
Min Typ Max Min
Max
Unit
1.5 — — 1.5
—
V
3.15 — — 3.15 —
4.2 — — 4.2
—
— — 0.5 —
0.5
V
— — 1.35 —
1.35
— — 1.8 —
1.8
— 2000 5000 —
6250 Ω
— 100 200 —
250
— 60 170 —
210
— — ±0.1 —
±1.0 µA
— — ±0.1 —
— — ±0.1 —
— — 1.0 —
±1.0 µA
±1.0 µA
10.0 µA
Test Conditions
VC = VIH
VIN = 0 to VCC
IIN/OUT = 1 mA
VC = VIL
VIN = VCC, VOUT = GND
or VIN = GND, VOUT = VCC
VC = VIH
VIN = VCC or GND
VIN = VCC or GND
VIN = VCC or GND