µ PC1935
3.5 ON/OFF Control
3.5.1 Channel 1 (for step-up)
The ON/OFF signal control method of the output oscillation of channel 1 is to input the ON/OFF signal from ON1 as
shown in Figure 3-3. For channel 1, soft start or timer latch (SCP) is internally selected. Soft start is executed when the
first start signal is input. When the end of soft start is detected, the soft start select switch is turned OFF and the timer
latch circuit operates.
Figure 3-3 ON/OFF Control (channel 1 for step-up)
VO1
(Converter
output
R11
voltage)
R12
D11
ON1
Q11
CDLY
FB1
II1
–
+ Error amplifier
0.3 V
VREF
R1
Dead time
setting: 85 %
(internally fixed)
SCP comparator
(common to each channel)
+
Q1
–
0.63 V
To output stage
+
+
–
PWM comparator
Oscillation section
SW (common to each channel)
DLY
(1) When ON1 is high: OFF status
Q11: ON → DLY pin: Low level → Output duty of PWM comparator: 0 %
D11: ON → II1 pin: High level → FB1 output: Low level
(2) When ON1 is low: ON status (start up)
Q11: OFF → CDLY is charged in the sequence of [VREF → R1 → SW → DLY pin → CDLY] → Soft start
D11: OFF → II1 pin: Low level → FB1 output: High level
(3) When ON1 goes high again after start up (SW: OFF): OFF status
Q11: ON → DLY pin: Low level (Nothing happens because SW is OFF.)
D11: ON → II1 pin: High level → FB1 output: Low level → PWM comparator output duty: 0 %
→ Converter output voltage (VO1) drops.
Caution Even if start up is executed by making ON1 low again after (3), soft start is not executed because the
soft start select switch (SW) remains OFF. To execute soft start of channel 1 again, drop VCC to 0 V
once.