SPECIFICATION
RTL8019AS
6.2. Plug and Play
6.2.1. Initiation Key
The Plug and Play logic is quiescent on power up and must be enabled by software. This is done
by a predefined series of writes (32 I/O writes) to the ADDRESS port, which is called the
initiation key. The write sequence is decoded by RTL8019AS. If the proper series of I/O writes is
detected, then the Plug and Play auto-configuration ports are enabled. The write sequence will be
reset and must be issued from the beginning if any data mismatch occurs. The exact sequence for
the initiation key is listed below in hexadecimal notation.
PnP Initiation Key
6A, B5, DA, ED, F6, FB, 7D, BE,
DF, 6F, 37, 1B, 0D, 86, C3, 61,
B0, 58, 2C, 16, 8B, 45, A2, D1,
E8, 74, 3A, 9D, CE, E7, 73, 39
RT Initiation Key
DA, 6D, 36, 1B, 8D, 46, 23, 91,
48, A4, D2, 69, 34, 9A, 4D, 26,
13, 89, 44, A2, 51, 28, 94, CA,
65, 32, 19, 0C, 86, 43, A1, 50